• Beryl Battery Pack Testing Machine
  • Beryl Battery Pack Testing Machine
  • Beryl Battery Pack Testing Machine
  • Beryl Battery Pack Testing Machine
  • Beryl Battery Pack Testing Machine

Beryl Battery Pack Testing Machine

After-sales Service: All Parts of The Tester
Warranty: One Year
Type: Storage Battery Tester
Samples:
US$ 10000/Piece 1 Piece(Min.Order)
| Order Sample
battery pack tester
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Beryl Battery Pack Testing Machine pictures & photos
Beryl Battery Pack Testing Machine
US $10,000-16,000 / Piece
Min. Order: 1 Piece
Gold Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
BRE6000-100V100A
Test Region
All
Application
Lithium-ion Battery
Customized
Customized
Energy
Feedback to Grid
EV Battery Pack
Tester
Transport Package
Wooden Case Packing
Specification
800mm*600mm*1750mm
Trademark
Beryl
Origin
China
HS Code
9030339000
Production Capacity
500PCS/Month

Packaging & Delivery

Package Size
100.00cm * 80.00cm * 198.00cm
Package Gross Weight
150.000kg
Lead Time
30 days (1 - 1 Pieces)
To be negotiated ( > 1 Pieces)

Product Description

 
Product model code BRE-6000-Li/100V/30A/16 BRE-6000-Li/100V/60A/8 BRE-6000-Li/100V/100A/8
Output per channel 100V/30A      100V/60A 100V/100A
Channel number 16       8     8
Channel output access line
 
Positive and negative current wires for charging and discharging: connected to the positive and negative poles of the battery module
Voltage detection line: used for voltage detection of the battery module, generally connected to the positive and negative poles of the battery module
CAN communication interface: used to communicate with the BMS or BMU of the battery module
Temperature detection interface: optional
Input power 3AC380V ±10%/50Hz
Max input power     52KW     52KW       90KW
Wiring method of power cabinet Three-phase five-wire connection
Power factor of the whole machine ≥0.99  (Load power is more than 30% of full load power)
THD of whole machine THD5%
Efficiency The conversion efficiency of each link is greater than 85%
Noise 65dB
Voltage Setting range :0.1V~100V
Min. discharge voltage :5V~100V
Measurement range 0V~100V
Resolution            16AD
Control accuracy ±(0.05%RD+0.05%FS) ±(0.05%RD+0.05%FS)
Measurement accuracy ±(0.05%RD+0.05%FS) ±(0.05%RD+0.05%FS)
Current Measurement accuracy 0.1A~30A 0.1A~60A 0.1A~100A
Range of charge 0.1A~30A 0.1A~60A 0.1A~100A
Range of Measurement 0A~30A 0A~00A 0A~100A
Resolution                16AD,DA
Control accuracy ±(0.05%RD+0.05%FS)
Measurement accuracy ±(0.05%RD+0.05%FS)
  Temperature drift coefficient 25PPM/ºC
Power Max output power per channel 3000W    6000W   10000W
Time Channel sampling time 0.1s
Current response time 20ms 
Maximum current rise time
Step setting time range 1min~1024min
Timer accuracy ±0.01%
 Step setting method  Form edit (Maximum working steps 128)
Data record Recording conditions △T:1s~60min
Charge Charge mode Constant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging, constant resistance charging
 
Stop conditions
Voltage, current, time, capacity, -ΔV, battery module internal circuit protection
Discharge Discharge mode Constant current discharge, constant power discharge, constant resistance discharge
Stop conditions Pack voltage, cell voltage, current, time, capacity, battery module internal circuit protection
Loop Number of loop 1~30000
Step per loop 126
Protection method Hardware protection Battery reverse polarity protection
Short circuit protection
Output voltage surge protection
Circuit bad contact protection
Battery voltage double loop measurement protection
Software protection ower-down data protection
Offline data protection
Protection method Software protection Lower limit voltage, upper limit voltage, lower limit current, upper limit current, upper limit capacity, upper limit temperature parameter setting protection
Channel features When the channel is in the state of charging and discharging, when the internal circuit of the load battery module is suddenly disconnected, the output voltage will not overshoot, which can effectively protect the power switching devices inside the module
Double closed-loop structure, constant current and constant voltage conversion can transition smoothly, which can effectively prevent the impact of current spikes and large currents on the battery module, and protect the battery module
Channel control mode Each channel can be set and controlled independently
BMS communication per channel Each channel has an independent CAN communication interface, which can communicate with the BMS or BMU of the battery module, read the relevant data such as the voltage and temperature of the single battery inside the module, and can display it in real time through the central computer or the upper computer
Database  MySQL, ACCESS database to centrally manage test data, compatible with Manufacturing Execution System (MES) for equipment, convenient for data collection of different equipment, delivery of control parameters and debugging and maintenance of communication (database format can be customized according to user requirements)
 
Data output method
Excel,Txt
Curve type Able to draw the corresponding relationship curves during the formation process of each battery, including voltage/time curve, current/time curve, capacity/time curve, capacity/voltage curve, etc.
 
Barcode scanning
Support barcode scanning function, which can be realized through battery barcode
 
The host computer communication method
TCP/IP protocol
Communication interface RJ45, 10M~1000M adaptive
 System expansion Expand communication through switches and routers
Cabinet type Applicable to various battery modules: the cabinet body adopts the terminal output form, the positive and negative poles of the battery module are connected in the form of crocodile clips or wire lugs, and other special connections are proposed by the supplier and specially customized.
Cabinet size (L*W*H):800mm×600×1750mm
IP protection level IP20

 
Beryl Battery Pack Testing MachineBeryl Battery Pack Testing MachineBeryl Battery Pack Testing MachineBeryl Battery Pack Testing Machine
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Beryl Battery Pack Testing Machine pictures & photos
Beryl Battery Pack Testing Machine
US $10,000-16,000 / Piece
Min. Order: 1 Piece
Gold Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Registered Capital
12500000 RMB
Plant Area
501~1000 square meters