Battery Charge and Discharge Machine /Mouule/Laboratory Test Equipment/Segmented Range Module Device

Product Details
Customization: Available
After-sales Service: All Parts of The Tester
Application: Electrical & Electronics
Still deciding? Get samples of US$ 700/Piece
Request Sample
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
12500000 RMB
Plant Area
501~1000 square meters
  • Battery Charge and Discharge Machine /Mouule/Laboratory Test Equipment/Segmented Range Module Device
  • Battery Charge and Discharge Machine /Mouule/Laboratory Test Equipment/Segmented Range Module Device
  • Battery Charge and Discharge Machine /Mouule/Laboratory Test Equipment/Segmented Range Module Device
  • Battery Charge and Discharge Machine /Mouule/Laboratory Test Equipment/Segmented Range Module Device
  • Battery Charge and Discharge Machine /Mouule/Laboratory Test Equipment/Segmented Range Module Device
  • Battery Charge and Discharge Machine /Mouule/Laboratory Test Equipment/Segmented Range Module Device
Find Similar Products

Basic Info.

Model NO.
BRE6000- 5V6A/10A/12A/20A/60A/100A-8CH
Specification
50*45*18
Trademark
Beryl
Origin
China
HS Code
9030390000

Product Description

BRE-6000-5V6A-8CHBattery testing machine

Product model code
BRE-6000-5V6A-8CH
,
channel voltage/current
5V,6A
Channel number 8
Input power single-phase AC220V ±10%/50Hz(:AC110V ±10%/60Hz)

Max input power
300W
Noise 65dB
Efficiency  85%The conversion efficiency of each link is greater than 85%
 Voltage Charging voltage range Charge :0V~5V
Discharge voltage range Discharge:0V~5V
Voltage resolutio 16AD,DA
Accuracy ±(0.05%RD+0.05%FS)
stability ±(0.05%RD+0.05%FS)
 
current
Channel output current range Range one :0.01mA~1mA; Range two:1mA~50mA;
 Range three:50mA~0.5A;Range four:0.5A~6A
Current range -6A~6A
Current resolution 16 bit AD,DA
Accuracy ±(0.05%RD+0.05%FS)
Constant voltage cut-off current Range one :2uA; Range two:0.1mA;
Range three:1mA;Range four:12mA
stability ±(0.05%RD+0.05%FS)


 Power
Maximum output power for a single channel 30W
stability ±(0.1%RD+0.1%FS)
 Time Current response time 5ms(10%FS~90%FS)
Maximum current rise time 5ms
Step setting time range ≤50*24H/Step Time format support
 00:00:00:00(h,min,s,ms)
Timer accuracy 1s/H

Step setting method
( 128)Table Editing (Maximum number of steps: 128)



Data record

Minimum recording time
100ms


record condition
Minimum time interval:100ms
Minimum voltage interval:10mV
Minimum current interval:Range one :2μA;
Range two:0.1mA;Range three:1mA
Range four:12mA
Charge
Charge mode
,,,,
Constant current charging, constant voltage charging, constant current constant voltage charging, constant power charging, constant resistance charging

Stop conditions
,,,,
Voltage, current, time, capacity
Discharge Discharge mode ,,
Constant current discharging, constant power discharging, constant resistance discharging
Stop conditions ,,,Voltage,time, capacity
Pulse Charge mode ,Constant current mode, constant power mode
Discharge mode ,Constant current mode, constant power mode
Minimum pulse width 100mS
Setting number of pulses maximum 60000
Charge-discharge switching
Supports direct switching from charging to discharging
 
Stop conditions ,,Voltage, pulse count, capacity
Slope Charge mode ,Current ramp charging, power ramp charging
Discharge mode ,Current ramp discharge, power ramp discharge

Stop conditions
,,, Ramp termination value, time, voltage, capacity
 Loop  Cycle measurement range 1~60000 times
Number of steps in a single loop 128
number of loops maximum65535
nested loop , 3 Supports nested loops with a maximum of 3 levels of nesting
DCIR  DCIR 
Support for custom sampling points for DCIR calculation
 protection Hardware protection ,,,
Battery reverse connection protection, short circuit protection, poor contact protection in the circuit, dual-loop measurement protection for battery voltage.
Software protection ,,,,,,,Power-off data protection, offline data protection when connected to the network, lower voltage limit, upper voltage limit, lower current limit, upper current limit, upper capacity limit, upper temperature limit parameter setting protection
PACKPack cell protection ,,,,Single cell under voltage, single cell over voltage, single cell temperature exceedance, battery reverse connection protection, adjustable protection limits

Channel features
;,,,;Discharge energy feedback to the grid; adopting a dual closed-loop structure, constant current and constant voltage conversion can smoothly transition, effectively preventing current spikes and large currents from impacting the battery cells, protecting the battery cells. With temperature for each channel.
current and voltage detection sampling four-wire system

Channel control mode
Each channel can be set and controlled independently

Database
 SQL,MySQL,ACCESS , (MES),( )Using SQL, MySQL, ACCESS database to centrally manage test data, compatible with Manufacturing Execution System (MES) for equipment, convenient for data collection of different equipment, delivery of control parameters and debugging and maintenance of communication (database format can be customized according to user requirements)
Data output method Excel,Txt
Curve type ,/, /, /,/Able to draw the corresponding relationship curves during the formation process of each battery, including voltage/time curve, current/time curve, capacity/time curve, capacity/voltage curve, etc.
Barcode scanning ,Support barcode scanning function, which can be realized through battery barcode
The host computer communication method  TCP/IP 
TCP/IP protocol
Communication interface (RJ45),10M~1000M
RJ45, 10M~1000M adaptive
System expansion
Expand communication through switches and routers
Cabinet type Applicable for battery cell testing
IP IP protection level IP20
Index item index parameter
temperature Range of working temperature-10ºC~40ºC
Storage temperature range-20ºC~60ºC
Humidity <=80% RH()
Working environment relative humidity<=80% RH (no water vapor condensation)
<=85% RH()
Storage environment relative humidity<=85% RH (no water vapor condensation)
Battery Charge and Discharge Machine /Mouule/Laboratory Test Equipment/Segmented Range Module DeviceBattery Charge and Discharge Machine /Mouule/Laboratory Test Equipment/Segmented Range Module DeviceBattery Charge and Discharge Machine /Mouule/Laboratory Test Equipment/Segmented Range Module DeviceBattery Charge and Discharge Machine /Mouule/Laboratory Test Equipment/Segmented Range Module Device