Customization: | Available |
---|---|
After-sales Service: | All Parts of The Tester |
Application: | Electrical & Electronics |
Still deciding? Get samples of US$ 700/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
BRE-6000-5V6A-8CHBattery testing machine | |||
Product model code |
BRE-6000-5V6A-8CH | ||
, channel voltage/current |
5V,6A | ||
Channel number | 8 | ||
Input power | single-phase AC220V ±10%/50Hz(:AC110V ±10%/60Hz) | ||
Max input power |
300W | ||
Noise | ≤65dB | ||
Efficiency | 85%The conversion efficiency of each link is greater than 85% | ||
Voltage | Charging voltage range | Charge :0V~5V | |
Discharge voltage range | Discharge:0V~5V | ||
Voltage resolutio | 16AD,DA | ||
Accuracy | ±(0.05%RD+0.05%FS) | ||
stability | ±(0.05%RD+0.05%FS) | ||
current |
Channel output current range | Range one :0.01mA~1mA; Range two:1mA~50mA; Range three:50mA~0.5A;Range four:0.5A~6A |
|
Current range | -6A~6A | ||
Current resolution | 16 bit AD,DA | ||
Accuracy | ±(0.05%RD+0.05%FS) | ||
Constant voltage cut-off current | Range one :2uA; Range two:0.1mA; Range three:1mA;Range four:12mA |
||
stability | ±(0.05%RD+0.05%FS) | ||
Power |
Maximum output power for a single channel | 30W | |
stability | ±(0.1%RD+0.1%FS) | ||
Time | Current response time | 5ms(10%FS~90%FS) Maximum current rise time 5ms |
|
Step setting time range | ≤50*24H/Step | Time format support 00:00:00:00(h,min,s,ms) |
|
Timer accuracy | 1s/H | ||
Step setting method |
( 128)Table Editing (Maximum number of steps: 128) | ||
Data record |
Minimum recording time |
100ms | |
record condition |
Minimum time interval:100ms | ||
Minimum voltage interval:10mV | |||
Minimum current interval:Range one :2μA; Range two:0.1mA;Range three:1mA Range four:12mA |
|||
Charge | Charge mode |
,,,, Constant current charging, constant voltage charging, constant current constant voltage charging, constant power charging, constant resistance charging |
|
Stop conditions |
,,,, Voltage, current, time, capacity |
||
Discharge | Discharge mode | ,, Constant current discharging, constant power discharging, constant resistance discharging |
|
Stop conditions | ,,,Voltage,time, capacity | ||
Pulse | Charge mode | ,Constant current mode, constant power mode | |
Discharge mode | ,Constant current mode, constant power mode | ||
Minimum pulse width | 100mS | ||
Setting number of pulses | maximum 60000 | ||
Charge-discharge switching | Supports direct switching from charging to discharging |
||
Stop conditions | ,,Voltage, pulse count, capacity | ||
Slope | Charge mode | ,Current ramp charging, power ramp charging | |
Discharge mode | ,Current ramp discharge, power ramp discharge | ||
Stop conditions |
,,, Ramp termination value, time, voltage, capacity | ||
Loop | Cycle measurement range | 1~60000 times | |
Number of steps in a single loop | 128 | ||
number of loops | maximum65535 | ||
nested loop | , 3 Supports nested loops with a maximum of 3 levels of nesting | ||
DCIR | DCIR Support for custom sampling points for DCIR calculation |
||
protection | Hardware protection | ,,, Battery reverse connection protection, short circuit protection, poor contact protection in the circuit, dual-loop measurement protection for battery voltage. |
|
Software protection | ,,,,,,,Power-off data protection, offline data protection when connected to the network, lower voltage limit, upper voltage limit, lower current limit, upper current limit, upper capacity limit, upper temperature limit parameter setting protection | ||
PACKPack cell protection | ,,,,Single cell under voltage, single cell over voltage, single cell temperature exceedance, battery reverse connection protection, adjustable protection limits | ||
Channel features |
;,,,;Discharge energy feedback to the grid; adopting a dual closed-loop structure, constant current and constant voltage conversion can smoothly transition, effectively preventing current spikes and large currents from impacting the battery cells, protecting the battery cells. With temperature for each channel. | ||
current and voltage detection sampling | four-wire system | ||
Channel control mode |
Each channel can be set and controlled independently | ||
Database |
SQL,MySQL,ACCESS , (MES),( )Using SQL, MySQL, ACCESS database to centrally manage test data, compatible with Manufacturing Execution System (MES) for equipment, convenient for data collection of different equipment, delivery of control parameters and debugging and maintenance of communication (database format can be customized according to user requirements) | ||
Data output method | Excel,Txt | ||
Curve type | ,/, /, /,/Able to draw the corresponding relationship curves during the formation process of each battery, including voltage/time curve, current/time curve, capacity/time curve, capacity/voltage curve, etc. | ||
Barcode scanning | ,Support barcode scanning function, which can be realized through battery barcode | ||
The host computer communication method | TCP/IP TCP/IP protocol |
||
Communication interface | (RJ45),10M~1000M RJ45, 10M~1000M adaptive |
||
System expansion | Expand communication through switches and routers |
||
Cabinet type | Applicable for battery cell testing | ||
IP IP protection level | IP20 |
Index item | index parameter |
temperature | Range of working temperature-10ºC~40ºC |
Storage temperature range-20ºC~60ºC | |
Humidity | <=80% RH() Working environment relative humidity<=80% RH (no water vapor condensation) |
<=85% RH() Storage environment relative humidity<=85% RH (no water vapor condensation) |