Product model code |
BRE-6000-5V/3A/8 |
Output per channel |
5V/3A |
Channel number |
8 |
Input power |
Three-phase five-wire connection AC380V ±10%/50Hz |
Max input power |
150W |
Noise |
≤75dB |
Power factor of the whole machine |
≥0.99(Load power is more than 30% of full load power) |
THD of whole machine |
THD≤5% |
Efficiency |
The conversion efficiency of each link is greater than 85% |
Voltage |
Charging voltage range |
Charge :0V~5V(Default cable length) |
Discharge voltage range |
Discharge :1.5V~5V(Default cable length) |
Voltage resolution |
16 bit AD,DA |
Accuracy |
±(0.05%RD+0.05%FS) |
current |
Current range |
-3A~3A |
Minimum current |
20mA |
Current resolution |
16 bit AD,DA |
Accuracy |
±(0.05%RD+0.05%FS) |
Power |
Maximum output power for a single channel |
15kW |
Time |
Channel sampling time |
0.1s |
Current response time |
Maximum current rise time 20ms |
Step setting time range |
≤50*24 hour/step |
Timer accuracy |
1s/H |
Step setting method |
Table Editing (Maximum number of steps: 128) |
Data record |
Minimum recording time |
100ms |
Recording mode |
Time difference:0.1~9999S |
Voltage difference:0.1%FS~100%FS |
Current difference:0.1%FS~100%FS |
Charge |
Charge mode |
Constant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging, constant resistance charging |
Stop conditions |
Voltage, current, time, capacity |
Discharge |
Discharge mode |
Constant current discharge, constant power discharge, constant resistance discharge |
Stop conditions |
Voltage,time, capacity |
Pulse |
Charge mode |
Constant current mode, constant power mode |
Discharge mode |
Constant current mode, constant power mode |
Minimum pulse width |
100mS |
Stop conditions |
Voltage, pulse count, capacity |
Slope |
Charge mode |
Current ramp charging, power ramp charging |
Discharge mode |
Current ramp discharge, power ramp discharge |
Stop conditions |
Ramp termination value, time, voltage, capacity |
Loop |
Cycle measuremet range |
1~60000 |
Number of steps in a single loop |
126 |
protection |
Hardware protection |
Battery reverse connection protection, short circuit protection, poor contact protection in the circuit, dual-loop measurement protection for battery voltage. |
Software protection |
Power-off data protection, offline data protection when connected to the network, lower voltage limit, upper voltage limit, lower current limit, upper current limit, upper capacity limit, upper temperature limit parameter setting protection |
Pack cell protection |
Single cell undervoltage, single cell overvoltage, single cell temperature exceedance, battery reverse connection protection, adjustable protection limits |
Channel features |
Discharge energy feedback to the grid; adopting a dual closed-loop structure, constant current and constant voltage conversion can smoothly transition, effectively preventing current spikes and large currents from impacting the battery cells, protecting the battery cells |
Channel control mode |
Each channel can be set and controlled independently |
Channel function expansion |
Each channel can be customized to include multiple auxiliary voltage/temperature channels. Each channel has a CAN communication port, enabling the reading of cell data from pack modules based on protocols |
Database |
Using SQL, MySQL, ACCESS database to centrally manage test data, compatible with Manufacturing Execution System (MES) for equipment, convenient for data collection of different equipment, delivery of control parameters and debugging and maintenance of communication (database format can be customized according to user requirements) |
Data output method |
Excel,Txt |
Curve type |
Able to draw the corresponding relationship curves during the formation process of each battery, including voltage/time curve, current/time curve, capacity/time curve, capacity/voltage curve, etc. |
Barcode scanning |
Support barcode scanning function, which can be realized through battery barcode |
The host computer communication method |
TCP/IP protocol |
Communication interface |
RJ45, 10M~1000M adaptive |
System expansion |
Expand communication through switches and routers |
Cabinet type |
Applicable to various battery modules: the cabinet body adopts the terminal output form, the positive and negative poles of the battery module are connected in the form of crocodile clips or wire lugs, and other special connections are proposed by the supplier and specially customized. |
IP protection level |
IP20 |