Customization: | Available |
---|---|
After-sales Service: | All Parts of The Tester |
Application: | Electrical & Electronics |
Still deciding? Get samples of US$ 700/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product model code | BRE-6000-20V/60A/2 | |
channel voltage/current | 20V/60A | |
Channel number | 2 | |
Input power | Three-phase AC380V ±10%/50Hz | |
Max input power |
3KW | |
Noise | ≤75dB | |
Power factor of the whole machine | ≥0.99(Load power is more than 30% of full load power) | |
THD of whole machine |
THD≤5% | |
Efficiency | The conversion efficiency of each link is greater than 85% | |
Voltage | Charging voltage range | Charge :0V~20V |
Discharge voltage range | Discharge :2V~20V | |
Voltage resolution | 16 bit AD,DA | |
Accuracy | ±(0.05%RD+0.05%FS) | |
current |
Current range | -60A~60A |
Minimum current | 120mA | |
Current resolution | 16 bit AD,DA | |
Accuracy | ±(0.05%RD+0.05%FS) | |
Power | Maximum output power for a single channel | 1200W |
Time |
Channel sampling time | 0.1s |
Current response time | Maximum current rise time 20ms | |
Step setting time range | ≤50*24 hour/step | |
Timer accuracy | 1s/H | |
Step setting method |
18 Table Editing (Maximum number of steps: 128) |
|
Data record |
Minimum recording time | 100ms |
Recording mode |
Time difference:0.1~9999S | |
Voltage difference:0.1%FS~100%FS | ||
Current difference:0.1%FS~100%FS | ||
Charge |
Charge mode |
,,, ,Constant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging, constant resistance charging |
Stop conditions |
,,,Voltage, current, time, capacity | |
Discharge |
Discharge mode | ,, Constant current discharge, constant power discharge, constant resistance discharge |
Stop conditions |
,,Voltage,time, capacity | |
Pulse |
Charge mode | ,Constant current mode, constant power mode |
Discharge mode | ,Constant current mode, constant power mode | |
Minimum pulse width | 100mS | |
Stop conditions | ,,Voltage, pulse count, capacity | |
Slope |
Charge mode | ,Current ramp charging, power ramp charging |
Discharge mode | ,Current ramp discharge, power ramp discharge | |
Stop conditions | ,,,Ramp termination value, time, voltage, capacity | |
Loop | Cycle measurement range | 1~60000 times |
Number of steps in a single loop | 128 | |
DCIR | DCIR Support for custom sampling points for DCIR calculation |
|
protection | Hardware protection | ,,,Battery reverse connection protection, short circuit protection, poor contact protection in the circuit, dual-loop measurement protection for battery voltage. |
Software protection | ,,,,,,Power-off data protection, offline data protection when connected to the network, lower voltage limit, upper voltage limit, lower current limit, upper current limit, upper capacity limit | |
PACKPack cell protection | ,,,,Single cell under voltage, single cell over voltage, single cell temperature exceedance, battery reverse connection protection, adjustable protection limits | |
Channel features |
;,,,,Discharge energy feedback to the grid; adopting a dual closed-loop structure, constant current and constant voltage conversion can smoothly transition, effectively preventing current spikes and large currents from impacting the battery cells, protecting the battery cells. Each channel with temperature | |
Channel control mode | Each channel can be set and controlled independently |
|
Database |
SQL,MySQL,ACCESS , (MES),( )Using SQL, MySQL, ACCESS database to centrally manage test data, compatible with Manufacturing Execution System (MES) for equipment, convenient for data collection of different equipment, delivery of control parameters and debugging and maintenance of communication (database format can be customized according to user requirements) | |
Data output method |
Excel,Txt | |
Curve type | ,/, /, /,/Able to draw the corresponding relationship curves during the formation process of each battery, including voltage/time curve, current/time curve, capacity/time curve, capacity/voltage curve, etc. | |
Barcode scanning | ,Support barcode scanning function, which can be realized through battery barcode | |
The host computer communication method | TCP/IP protocol | |
Communication interface | RJ45, 10M~1000M adaptive | |
System expansion | Expand communication through switches and routers | |
Cabinet type | pack, Applicable for battery pack testing and Connect the battery with a wire nose. Reference size:45cm*50cm*15cm. |
|
IP protection level | IP20 | |
Software |
V1.1 Battery formation and capacity grading systemV1.1 |
|
V1.0 Battery formation and grading system middleware software |