Product model code |
BRE-6000-5V/1A/512 | BRE-6000-5V/3A/512 | BRE-6000-5V/6A/256 | BRE-6000-5V/10A/256 |
Output per channel |
5V/1A | 5V/3A | 5V/6A | 5V/10A |
Channel number |
512 | 512 | 512,256 | 256,96 |
Number of parallel units per channel |
1 | 1 | 1 | 1 |
Input power | 3-phase AC 380V ±10%/50Hz |
|||
Max input power |
3KW | 9KW | 18KW | 16KW |
Noise |
≤65dB | |||
Wiring method of power cabinet |
Three-phase five-wire connection |
Power factor of the whole machine |
≥0.99 (Load power is more than 30% of full load power) |
THD of whole machine | THD≤5% |
Efficiency |
The conversion efficiency of each link is greater than 85% |
||||
Voltage |
Setting range |
0.02V~5V | |||
Min. discharge voltage | 1V~5V | ||||
Measurement range |
0V~5V | ||||
Resolution |
0.1mV | ||||
Control accuracy |
±(0.05%RD+0.05%FS) | ||||
Measurement accuracy |
±(0.05%RD+0.05%FS) | ||||
Current |
Range of charge |
1mA~1A | 0.01A~3A | 0.02A~6A | 0.05A~10A |
Range of discharge |
1mA~1A | 0.01A~3A | 0.02A~6A | 0.05A~10A | |
Range of Measurement |
0A~1A | 0A~3A | 0A~6A | 0A~10A | |
Resolution |
16-bit AD and DA |
||||
Control accuracy |
±(0.05%RD+0.05%FS) | ||||
Measurement accuracy |
±(0.05%RD+0.05%FS) | ||||
Temperature drift coefficient |
25PPM/ºC | ||||
Power |
Max output power per channel |
5W | 15W | 30W | 50W |
Time |
Channel sampling time |
0.1s |
Current response time |
10ms Maximum current rise time |
|
Step setting time range |
1min~1024min | |
Timer accuracy |
±0.01% | |
Step setting method |
Form edit (Maximum working steps 128) |
|
Data record |
Recording conditions |
ΔT:1s~60min |
Charge | Charge mode |
Constant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging, constant resistance charging |
Stop conditions | Voltage, current, time, capacity, - ΔT | |
Discharge |
Discharge mode |
Constant current discharge, constant power discharge, constant resistance discharge |
Stop conditions |
Voltage, current, time, capacity |
|
Loop |
Number of loop |
1~30000 |
Step per loop |
126 | |
Protection method |
Hardware protection |
Battery reverse polarity protection |
Short circuit protection | ||
Output voltage surge protection | ||
Battery voltage double loop measurement protection | ||
Software protection |
Power-down data protection | |
Offline data protection |
Index item | index paramete |
temperature | (Range of working temperature) -10ºC~40ºC |
(Storage temperature range) -20ºC~60ºC | |
Humidity | Working environment relative humidity<=80% RH (no water vapor condensation) |
Storage environment relative humidity<=85% RH (no water vapor condensation) |